Armored fiber optic cable with build-in metal armor can provide stronger protection of the optical fibers than standards fiber optic cables. The rugged armored cables allow optical fiber to be installed in the most hazardous areas, including environments with slight dust, oil, gas, moisture, or even damage-causing rodents.
Please note: E2000 is an LSH connector with a dust-proof cover.
Click to open expanded view
Customized Duplex OS2 Single Mode LC/SC/FC/ST/LSH Armored 3.0mm Fiber Optic Patch Cable
Hot #20720
Hot #20720
SGD13.08 (Incl. GST)
FS P/N: AM-OS2XXDX
38.7K Sold
108 Reviews
15 Questions
Choose Length:
1m (3ft)
2m (7ft)
3m (10ft)
5m (16ft)
10m (33ft)
15m (49ft)
20m (66ft)
30m (98ft)
m
1m (3ft)
2m (7ft)
3m (10ft)
5m (16ft)
10m (33ft)
15m (49ft)
20m (66ft)
30m (98ft)
m
Connector A:
LC UPC
Connector B:
LC UPC
Cable Jacket:
PVC
Pulling Eye:
None
Pre-order, Ship by 28 Jun 2024
See more Warehouse
Deliver to Singapore, 178958
SGD34.00 via DHL Express Worldwide
Project Inquiry
Solution Design
Outstanding Single Mode Indoor Armored Fiber Optic Cables
Specifications
Connector Type
LC/SC/ST/FC/LSH
Polish Type
UPC/APC
Fiber Mode
OS2 9/125 μm
Wavelength
1310/1550 nm
Fiber Count
Duplex
Polarity
A (Tx) to B (Rx)
Fiber Grade
G.657.A1
Min. Bend Radius
10/5D (Dynamic/Static)
Cable Jacket
PVC/LSZH/OFNP
Tensile Load
120/225N (Long/Short Term)
Insertion Loss
≤0.3dB
Return Loss
UPC≥50dB, APC≥60dB (LC/SC/ST/FC)
UPC≥55dB, APC≥75dB (LSH)
UPC≥55dB, APC≥75dB (LSH)
Operating Temperature
-25~70°C
Storage Temperature
-25~70°C
Quality Certifications
To get the detailed certification, please go to the Product Compliance Status for download.
Features
Tough Steel Tube Protects Network Connection Further
Stainless steel tube can provide good protection against optical fiber breakage and be used in a slight oil, gas and moisture environment, which ensure the operation of the network.
Trampling Resistance
Moisture Resistance
Gas Resistance
Oil Resistance
Rodents/Pests Resistance
Carrier-grade Cable with Guaranteed Quality
10/5D Min. Bend Radius
The G.657.A1 fiber allows tighter cable bends for routing.
Zirconia Ceramic Ferrule
The precision ferrules reach up to 1000 times times insertions lifespan.
120-225N Tensile Strength
The pull-resistant cable prevents breaking and prolongs the life.
Two Polish Types for Various Signal Sensitivity Demands
The fiber endfaces of UPC and APC result in different signal losses. With an 8° angled endface, APC
is more suitable for high precision fiber optic signal applications.
is more suitable for high precision fiber optic signal applications.
UPC mainly used for TV, telephony and data systems.
APC mainly used for FTTX, PON and other WDM systems.
Three Jacket Materials Used in Diverse Cabling Zone
It's important to know the differences between OFNP, PVC, LSZH jackets because each different type is used in different locations.
Meet the Various Indoor Installation Needs
Ideal for network cabinet connection, ceiling wiring and under-floor wiring in the data center.
Videos
Questions & Answers
Ask a question
All (15)Application (1)Cable Structure (1)Custom Color (1)Customization (1)Double Armor (1)Fiber Grade (1)Minimum Compressive Strength (1)Minimum Length (1)Multifiber Cable (1)Product Comparison (1)Pulling Eye (1)Stainless Grade (1)Tensile Strength (1)Waterproof (1)
Customer Reviews
Write a review
5
stars
4
stars
3
stars
2
stars
1
star
90
18
0
0
0
M***l
United States
May 24, 2023
FS makes high grade cables. I use these in both my personal projects as well as professional environment and have never been let down in 3 years of running them.
Verified Purchase
Helpful 0
Comment 0G***u
France
April 12, 2023
My company is deploying a network for a medical building. We use your armored patch cords inside our house and underground and are very pleased!
Verified Purchase
Helpful 0
Comment 0D***d
Austria
April 04, 2023
Absolut Hochflexibel, selbst unter schwierigsten Verlegebedingungen nimmt das Kabel keinen Schaden.
Durch den Schutz der Faser durch das Edelstahl-Wellrohr ist es auch extrem robust. Würde ich es jederzeit wieder verwenden.
Absolutely highly flexible, even under the most difficult installation conditions, the cable does not suffer any damage.
Due to the protection of the fiber by the corrugated stainless steel tube, it is also extremely robust. Would I use it again at any time.
Durch den Schutz der Faser durch das Edelstahl-Wellrohr ist es auch extrem robust. Würde ich es jederzeit wieder verwenden.
Absolutely highly flexible, even under the most difficult installation conditions, the cable does not suffer any damage.
Due to the protection of the fiber by the corrugated stainless steel tube, it is also extremely robust. Would I use it again at any time.
Verified Purchase
Helpful 0
Comment 0See all reviews