Switched PDU can locally monitor load level and avoid potential overloads with a LCD hot swapping display, as well as remotely control individual outlets for the rebooting of locked equipment to avoid costly service calls, custom power-on/power-off sequences and load-shedding of non-essential loads during blackouts to extend battery backup runtime for critical equipment. The PDUs network interface connects to an Ethernet jack. Remote users can switch each of the PDUs outlets on or off via SNMP and Web.Remote outlet level control allows on/off power cycling to remotely restart equipment and limits unauthorized use of individual outlets to reduce downtime.Outlet power sequencing and grouping allows the user to specify the device power-on or power-down sequence to avoid overloading the circuit due to inrush current or load reduction to save energy.
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/550x550/74158.main.jpg)
Click to open expanded view
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.main.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.B.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.C.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.D.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.E.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.F.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.G.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.H.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.I.jpg)
![21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical This picture is about PDU-3PNE24I-VSW.](https://resource.fs.com/mall/products/60x60/74158.J.jpg)
21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical
21.06kW 3-Phase 32A/380V Switched PDU, 21 C13 & 3 C19 Outlets, IEC309 32A 3P+N+E Plug, 10ft Cord, 0U Vertical
Ensure the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices. Also extend the life of the product.
Pure Copper Chip Power Cord
Long length reaches distant power sources, more flexible.
Durable Metal Housing
Excellent flame retardancy and heat dissipation, long service life.
High Quality Copper Strip
Safe and stable internal structure, good electrical conductivity.
PDU maximizes data center efficiency by delivering intelligence, advanced alerting, and visibility into your power chain.
Product Type | Basic | Metered | Monitored | Switched | Switched Metered-by-Outlet |
Circuit Breaker | — | 2, Magnetic-hydraulic | 2, Magnetic-hydraulic | 3, Magnetic-hydraulic | 3, Hydraulic |
Individual Switch Control | — | — | — | ||
Alarm Indicator | |||||
Individual Outlet Monitoring | — | — | — | — | |
Buzzer Beeping | — | ||||
User-defined Alarm | — | — | |||
Operation Log | — | ||||
Hot-swappable Ammeter | — | ||||
Network Access | — | — |