The 100GBASE-LR Single Lambda QSFP28 Optical Transceiver Module is designed for use in 100GBASE Ethernet throughput up to 10km over single mode fiber (SMF) using a wavelength of 1310nm via duplex LC connectors. The transceiver includes a Broadcom chip to convert the 4x25G NRZ electrical signals to a 1x100G PAM-4 optical signal. This transceiver is compliant with QSFP28 MSA, IEEE 802.3cd and 100G Lambda MSA standard. Digital diagnostics functions are also available via the I2C interface, as specified by the QSFP28 MSA, to allow access to real-time operating parameters. With these features, this easy to install, hot swappable transceiver is suitable to be used in various applications, such as Data Center, 100G Ethernet, 400G to 100G breakout applications.
Note: The FS P/N is changed from QSFP28-LR-100G to QSFP-LR-100G, but the product is the same. Only the FS P/N has been changed.
Cliquez sur l'image pour l'agrandir
Cisco QSFP-100G-LR-S Compatible Module QSFP28 100GBASE-LR Single Lambda 1310nm 10km DOM LC Duplex SMF
Cisco QSFP-100G-LR-S Compatible 100GBASE-LR Single Lambda QSFP28 PAM4 Optical Transceiver Module (Single Lambda, SMF, 1310nm, 10km, LC, DOM)
Caractéristiques
Technologie d'Emballage | COB | COB | BOX | BOX |
Débit de Données (Maxi.) | 103.1Gbps | 103.1Gbps (4 x 25.78Gbps) | 103.1Gbps (4 x 25.78Gbps) | 103.1Gbps (4 x 25.78Gbps) 112Gbps (4 x 28Gbps) |
Distance de Câble (Maxi.) | 10km @SMF | 10km @SMF | 10km @SMF | 10km @SMF |
Longueur d'onde | 1310nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm |
Puissance d'Émission | -1.4~4.5dBm | -4.3~4.5dBm | -4.3~4.5dBm | -4.3~4.5dBm @100G -0.6~4dBm @112G |
Sensibilité du Récepteur | <-7.7dBm | <-10.6dBm | <-10.6dBm | <-8.6dBm @100G <-8.4dBm @112G |
Surcharge du Récepteur | 4.5dBm | 4.5dBm | 4.5dBm | 4.5dBm @100G 4dBm @112G |
Consommation Électrique | 4.5W | 4W | 3.5W | 3.5W |
Formats de Modulation | PAM4 | NRZ | NRZ | NRZ |
Application | Centre de Données, 100G Ethernet, 400G à 100G Breakout | Centre de Données, 100G Ethernet | Télécoms, Centre de Données, 100G Ethernet | Télécoms, Centre de Données, 100G Ethernet et 112G OTN OTU4 |
Vidéos
Cisco QSFP-100G-LR-S Compatible 100GBASE-LR Single Lambda QSFP28 PAM4 Optical Transceiver Module (Single Lambda, SMF, 1310nm, 10km, LC, DOM)
The 100GBASE-LR Single Lambda QSFP28 Optical Transceiver Module is designed for use in 100GBASE Ethernet throughput up to 10km over single mode fiber (SMF) using a wavelength of 1310nm via duplex LC connectors. The transceiver includes a Broadcom chip to convert the 4x25G NRZ electrical signals to a 1x100G PAM-4 optical signal. This transceiver is compliant with QSFP28 MSA, IEEE 802.3cd and 100G Lambda MSA standard. Digital diagnostics functions are also available via the I2C interface, as specified by the QSFP28 MSA, to allow access to real-time operating parameters. With these features, this easy to install, hot swappable transceiver is suitable to be used in various applications, such as Data Center, 100G Ethernet, 400G to 100G breakout applications.
Note: The FS P/N is changed from QSFP28-LR-100G to QSFP-LR-100G, but the product is the same. Only the FS P/N has been changed.
Technologie d'Emballage | COB | COB | BOX | BOX |
Débit de Données (Maxi.) | 103.1Gbps | 103.1Gbps (4 x 25.78Gbps) | 103.1Gbps (4 x 25.78Gbps) | 103.1Gbps (4 x 25.78Gbps) 112Gbps (4 x 28Gbps) |
Distance de Câble (Maxi.) | 10km @SMF | 10km @SMF | 10km @SMF | 10km @SMF |
Longueur d'onde | 1310nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm | 1295.56nm 1300.05nm 1304.58nm 1309.14nm |
Puissance d'Émission | -1.4~4.5dBm | -4.3~4.5dBm | -4.3~4.5dBm | -4.3~4.5dBm @100G -0.6~4dBm @112G |
Sensibilité du Récepteur | <-7.7dBm | <-10.6dBm | <-10.6dBm | <-8.6dBm @100G <-8.4dBm @112G |
Surcharge du Récepteur | 4.5dBm | 4.5dBm | 4.5dBm | 4.5dBm @100G 4dBm @112G |
Consommation Électrique | 4.5W | 4W | 3.5W | 3.5W |
Formats de Modulation | PAM4 | NRZ | NRZ | NRZ |
Application | Centre de Données, 100G Ethernet, 400G à 100G Breakout | Centre de Données, 100G Ethernet | Télécoms, Centre de Données, 100G Ethernet | Télécoms, Centre de Données, 100G Ethernet et 112G OTN OTU4 |